| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 11-01-01 | Heat Capacity Measurement (with DSC) | Solid samples are studied. | 1032 |
| 11-01-02 | Determination of Melting Point and Glass Transition Temperature-between ambient temperature - 500 C temperatures (with DSC)-1 hour | Working range: Room temp.- 550 C | 1236 |
| 11-01-03 | Determination of Melting Point and Glass Transition Temperature-between ambient temperature - 500 C temperatures (with DSC)-2 hour | Working range: Room temp.- 550 C | 1440 |
| 11-01-04 | Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC)-1 hour | Working range:(-40) - 400 C | 864 |
| 11-01-05 | Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC)-2 hour | Working range:(-40) - 400 C | 1008 |
| 11-01-06 | Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC)-3 hour | Working range:(-40) - 400 C | 1152 |
| 11-01-07 | Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC)-4 hour | Working range:(-40) - 400 C | 1440 |
| 11-02-01 | Dew Point Temperature Measurement | Determination of dew point temperature in systems where humid air is used | 240 |
| 11-03-01 | Viscosity Measurement | Fluidity determination | 600 |
| 11-04-01 | Heat Conduction Coefficient Measurement (KEM-QTM500) | Working with powder samples. Measurement range: 0.023-11.23 W/mK | 1440 |
| 11-05-01 | Silica Measurement | Measuring range: 1 - 100 mg/L SiO 2 | 1100 |
| 11-06-01 | Heat Conduction Coefficient Measurement (TA-FOX314) | Measuring range: 0.005-0.35 W/mK | 1872 |
| 11-07-01 | Heat Conduction Coefficient Measurement (TA-FOX50) | Measuring range: 0.1-10 W/mK | 1872 |
| 11-08-01 | pH Measurement (Hach HQ2200) | Prices are valid for laboratory analysis. | 450 |
| 11-08-02 | Electrical Conductivity Measurement (Hach HQ2200) | Prices are valid for laboratory analysis. | 450 |
| 11-08-03 | Dissolved Oxygen Measurement (LDO)-(Hach HQ2200) | Prices are valid for laboratory analysis. | 450 |
| 11-08-04 | Analyses Pack pH-EC-LDO (Hach HQ2200) | Prices are valid for laboratory analysis. | 900 |
| 11-09-01 | Flame Photometer (Lithium-Potassium-Sodium) | Measuring range: 1-10 ppm. Price is per element. | 250 |
| 11-11-01 | Particle Count | Determination of airborne particle count | 360 |
| 11-12-01 | Building Indoor Air Quality Monitor | CO 2 , CO, Temperature, Relative Humidity | 504 |
| 11-13-01 | Thermal Comfort System | Temperature, air velocity, relative humidity, operative temperature, radiation temperature and dry heat loss temperature | 2520 |
| 11-21-01 | MicroGC | Determination of non-condensable gases from geothermal wells. Analysis price is per component. | 1000 |
| 11-22-01 | Tracer tests | It is used to determine the flow rate and groundwater flow direction. | 100000 |
| 11-23-01 | Radon Level Measurement (per point) | It is used for Radon gas determination in water, air and soil. | 3000 |
| 11-42-01 | Thermal Camera | Electrical, mechanical, insulation and handles all the problems with temperature in an open mechanism is used to instantly detect and diagnose. | 1236 |
| 11-43-01 | Conductivity Meter | For field measurement. Unit price for minimum 10 samples. Project design and service provided. | 480 |
| 11-44-01 | Steam Trap Tester | Used to detect steam leaks | 816 |
| 11-45-01 | Infrared Temperature Meter (Low Temperature) | Temperature measurement range: (-32) -420 °C | 480 |
| 11-46-01 | Infrared Temperature Meter (High Temperature) | Temperature measurement range: 200-1800 °C | 480 |
| 11-47-01 | Electronic Temperature Meters and Probes | Probes: Surface temperature probe, ambient temperature probe, skewer type temperature probe | 1200 |
| 11-48-01 | Ultrasonic Flow Meter | It is used to measure the flow of geothermal fluid inside the pipe. | 1200 |
| 11-49-01 | Electronic Relative Humidity Meter | Portable textile moisture measuring device | 552 |
| 11-51-01 | Hot Wire Air Velocity Meter (Device and Probe) | Used to measure air velocity, temperature, volumetric air flow, relative humidity and pressure | 552 |
| 11-52-01 | Propeller Type Air Velocity Meter | It is used to measure and record air velocity and temperature in air ducts. | 552 |
| 11-53-01 | Current Clamp | Current meter | 264 |
| 11-54-01 | Tachometer | 264 | |
| 11-55-01 | Lux-meter | Light intensity measurement | 552 |
| 11-56-01 | Sound Level Meter (hour) | Used to determine the level of noise in various environments | 792 |
| 11-61-01 | Geothermal Data Assessment Report | Interpretation of hydrological data from geothermal fields | 100000 |
| 11-61-02 | Geothermal Resource Protection Area Report | Prepared based on the Implementation Regulation of the Geothermal Resources and Natural Mineral Waters Law. Excluding tests. | 600000 |
| 11-61-03 | 1 / 25.000 Scale Hydrogeological Report (1km 2 ) | Includes the preparation of 1/25.000 scaled Hydrogeological Map for 1 km 2 area and report | 100000 |
| 11-61-04 | Preparation of 1 / 25.000 scaled Geological Maps and Sections that will be the basis for the exploration project of geothermal resources or natural mineral waters | It is prepared based on the Geothermal Resource or Natural Mineral Water Exploration Project (1 km2 area). | 75000 |
| 11-61-05 | Reservoir Modeling Study and Evaluation and Report Preparation of the geothermal resource (includes geology, geophysics, geochemistry, well logs, interpretation of hydrogeology data and modeling of the system) | Covers geology, geophysics, geochemistry, well logs, hydrogeology data interpretation and system modeling | 750000 |