Analysis CodeAnalysis NameExplanationPrice (TL)
14-01-01MALDI TOF MS – Molecular Mass Determination Same matrix is used in all samples. Price per sample.2000
(up to 5 Samples)
14-01-02MALDI TOF MS – Molecular Mass Determination Same matrix is used in all samples. Price per sample.1900
(between 6 and 10 Samples)
14-01-03MALDI TOF MS – Molecular Mass Determination Same matrix is used in all samples. Price per sample.1800
(between 11 and 20 Samples)
14-01-04MS/MS Analysis Price per ion.400
14-01-05MALDI TOF/TOF MS Protein Identification – Sample preparation not includedIt should be pre-cleaned through tryptic treatment, Ziptip etc.3500
14-01-06MALDI TOF/TOF MS Protein Identification – Sample preparation includedIn-sol/in-gel tryptic lysis and Ziptip cleaning are included in the analysis.5000
20 January 1900Orbitrap High Resolution nanoLC-MS 90 min. Proteomic analysisBlood serum/plasma samples are unsuitable for analysis.9000
23 January 1900Orbitrap High Resolution nanoLC-MS 150 min. Proteomic analysisBlood serum/plasma samples are unsuitable for analysis.12000
25 January 1900Orbitrap High Resolution nanoLC-MS non-complex peptide/protein analysisBlood serum/plasma samples are unsuitable for analysis.3500
27 January 1900Sample Preparation with FASP Tryptic Digestion (Filter digestion)It is applied to protein mixture. Blood serum/plasma samples are unsuitable for analysis.3000
30 January 1900Sample Preparation with Tryptic Digestion (In-solution / In-gel digestion)It is applied to protein mixture. Blood serum/plasma samples are unsuitable for analysis.2000
14-05-01Small Molecule Analysis - Orbitrap High Resolution (3 components max.)Sample in a vial should be prepared for the analysis. 750
14-05-02Small Molecule Analysis - Orbitrap High Resolution Reversed Phase LC-MSC18 column is used.2000
14-05-03Noncomplex Sample PreparationIncludes dissolving and vial fillng procedures that do not require special kit or filter.250
14-05-04Library Search for Small MoleculesFor the data collected whose LC-MS analysis is done outside NMSC.800
14-05-05Method Development for Small Molecule Analysis Necessary column, solvent and standards should be supplied.40000

NOTES :

  1. For bioinformatic analysis requiring peptide ID, protein database should be given in FASTA format, otherwise the reference proteome of the relevant organism is used via UniProt.
  2. Analyzes coded 14-01-05 and 14-01-06 include MS/MS analysis of at least 2 peptides with the strongest signals and database search with Mascot.
  3. For different methods than the ones requested in the 14-02-01 and 14-02-02 coded analyzes, the column, standard, solvents and literature study should be supplied by the user after the feasibility of the study is confirmed by the center.
  4. Standard shotgun method applied is DDA and label-free comparison is done for the analysis beginning with 14-03 code. Materials and applications specific to the study prior to sample preparation are the responsibility of the user. For detailed information, please contact the center.
  5.  C18 columns (reversed phase) are used for analysis 14-05-02. In other cases, after the suitability of the study is confirmed by the center, the column, standard, solvents and literature studies for the different requested methods are provided by the person requesting the analysis.