| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 10-01-01 | TEM Analysis | The device is not available for use | |
| 10-02-01 | SEM Analysis | An average of 6 samples can be investigated in 1 hour. The samples should not contain moisture/oil. | 500 TL/hr |
| 10-02-02 | EDX Analysis | An average of 6 samples can be investigated in 1 hour. The samples should not contain moisture/oil. | 600 TL/hr |
| 10-02-03 | STEM Analysis | An average of 2 samples can be investigated in 1 hour. The samples should not contain moisture/oil and should be prepared on TEM grid. | 900 TL/hr |
| 10-02-04 | ESEM Analysis | An average of 3 samples can be investigated in 1 hour. | 900 TL/hr |
| 10-02-05 | WETSTEM Analysis | Please make an appointment for SEM2 machine only Wednesday. You should contact the lecturer for sample suitability. | 1500 TL/hr |
| 10-02-06 | SEM - User | People who have taken SEM training and have been granted a right to use it can make an online appointment. | 125 TL/hr |
| 10-03-01 | AFM Analysis | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 900 TL/hr |
| 10-03-02 | Fulid Cell | The sample should be maximum 1 cm X 1 cm X 0.5 cm. The sample must be fixed to the surface. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 1200 TL/hr |
| 10-03-03 | Peak Force QNM | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 2000 TL/hr |
| 10-03-04 | Indentation | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Powder sample cannot be analyzed. | 2000 TL/hr |
| 10-04-01 | STM | The sample size should be maximum 1 cm X 1 cm X 0.5 cm. The sample should not contain moisture/oil. Samples must be conductive. Powder sample cannot be analyzed. | 2000 TL/hr |
| 10-11-01 | EDXRF | The sample should be at least 1 g. Particle size should be less than 100 microns. (If it is not in the desired size, the grinding option should be selected) Solid samples 32 mm or 40 mm diameter, maximum 10 mm height should be. When Fusion is desired, "Loss of Ignition" and "Fusion" pre-preparation processes should be selected. When the necessary preparation procedures are not selected, additions will be made by the expert. | 300 TL/piece |
| 10-12-01 | XRD Fast Scan Analysis (Standard), 0.08 ∘∕s , ∼17min | The amount of the sample must be the 1/4 of an eppendorf tube. Sample must be in fine powder form (100µ >). Scan range must be specified in the request form. | 200 TL/piece |
| 10-12-02 | XRD MediumScan Analysis (Standard), 0.04 ∘∕s, ∼ 33min | The amount of the sample must be the 1/4 of an eppendorf tube. Sample must be in fine powder form (100µ >) Scan range must be specified in the request form. | 250 TL/piece |
| 10-12-03 | XRD Low Scan Analysis (Standard), 0.02 ∘∕s, ∼65min | The amount of the sample must be the 1/4 of an eppendorf tube. Sample must be in fine powder form (100µ >) Scan range must be specified in the request form. | 300 TL/piece |
| 10-12-04 | Crystal Structure Analysis | XRD Analysis must have been acquired in IYTE CMR | 250 TL/hr |
| 10-14-01 | Spectrofluorometer (Solid Samples) | Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm Solid samples should be prepared as thin films. | 200 TL/hr |
| 10-14-02 | Spectrofluorometer (Liquid Samples) | Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm Amount of sample should be at least 100 μL. Liquid samples should be sent with their solvent. Samples should be sent with cuvettes. For Quantum Yield measurements, screw cap cuvettes are required. | 200 TL/hr |
| 10-21-01 | TGA Analysis - 1 hour | Sample amount should be between 3-10 mg. | 350 TL/piece |
| 10-21-02 | TGA Analysis - 2 hours | Sample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C. | 450 TL/piece |
| 10-21-03 | TGA Analysis - 3 hours | Sample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C. | 550 TL/piece |
| 10-21-04 | TGA Analysis - 4 hours | Sample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C. | 650 TL/piece |
| 10-22-01 | DSC Analysis- 1 hour | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 350 TL/piece |
| 10-22-02 | DSC Analysis-2 hours | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 450 TL/piece |
| 10-22-03 | DSC Analysis-3 hours | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 550 TL/piece |
| 10-22-04 | DSC Analysis-4 hours | Sample amount should be between 3-10 mg. The device works between -40 °C and 350 °C. | 650 TL/piece |
| 10-23-01 | Dilatometer | The device reaches a maximum of 1200 °C. Please contact the specialist to specify the size of your sample. | 400 TL/piece |
| 10-31-01 | BET Analysis | Sample amount should be at least 300 mg. Degas conditions must be specified. | 500 TL/piece |
| 10-31-02 | BET (Adsorption/Desorption) | Sample amount should be at least 300 mg. Degas conditions must be specified. | 700 TL/piece |
| 10-32-01 | Tensile | The thickness of the samples should be 8 mm maximum. The lecturer should be contacted. | 250 TL/piece |
| 10-32-02 | Compression | The lecturer should be contacted. | 250 TL/piece |
| 10-32-03 | High Temperature Tensile Testing | The lecturer should be contacted. | 600 TL/piece |
| 10-33-01 | Lecturer Report | It is prepared by the lecturer who is the expert of the device. | 1000 TL/piece |
| 10-33-02 | Faculty Member Report | It is prepared by member of teaching of IZTECH | 2000 TL/piece |
| Coating | 40 TL/piece | ||
| XRF Fusion | 120 TL/piece | ||
| Milling | 100 TL/piece | ||
| Loss of Ignition | 120 TL/piece |
| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 11-01-01 | Heat Capacity Measurement (with DSC) | Appointment is required | 360 TL |
| 11-01-02 | Determination of Melting Point and Glass Transition Temperature-between ambient temperature - 500 C temperatures (with DSC) | Working range: Room temp.- 550 C | 430 TL |
| 11-01-03 | Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC) | Working range:(-40) - 400 C | 290 TL |
| 11-02-01 | Dew Point Temperature Measurement | Determination of dew point temperature in systems where humid air is used | 70 TL |
| 11-03-01 | Viscosity Measurement | Fluidity determination | 145 TL |
| 11-04-01 | Heat Conduction Coefficient Measurement (KEM-QTM500) | Measuring range: 0.026-12 W/mK Minimum sample size: 2x6x12 cm | 190 TL |
| 11-05-01 | Silica Measurement | Measuring range: 1 - 100 mg/L SiO 2 | 170 TL |
| 11-06-01 | Heat Conduction Coefficient Measurement (TA-FOX314) | Measuring range: 0.005-0.35 W/mK | 840 TL |
| 11-07-01 | Heat Conduction Coefficient Measurement (TA-FOX50) | Measuring range: 0.1-10 W/mK | 840 TL |
| 11-08-01 | pH Measurement (Hach HQ2200) | Prices are valid for laboratory analysis. | 50 TL |
| 11-08-02 | Electrical Conductivity Measurement (Hach HQ2200) | Prices are valid for laboratory analysis. | 50 TL |
| 11-08-03 | Dissolved Oxygen Measurement (LDO)-(Hach HQ2200) | Prices are valid for laboratory analysis. | 50 TL |
| 11-08-04 | Analyses Pack pH-EC-LDO (Hach HQ2200) | Prices are valid for laboratory analysis. | 130 TL |
| 11-11-01 | Particle Count | Determination of airborne particle count | 215 TL |
| 11-12-01 | Building Indoor Air Quality Monitor | CO 2 , CO, Temperature, Relative Humidity | 290 TL |
| 11-13-01 | Thermal Comfort System | Temperature, air velocity, relative humidity, operative temperature, radiation temperature and dry heat loss temperature | 1440 TL |
| 11-21-01 | Downhole Temperature Measurement (per measurement) | Get information from the expert | 2160 TL |
| 11-21-01 | Downhole Pressure Measurement (per measurement) | Get information from the expert | 2160 TL |
| 11-22-01 | Tracer tests | It is used to determine the flow rate and groundwater flow direction. | 7200 TL |
| 11-23-01 | Radon Level Measurement (per point) | It is used for Radon gas determination in water, air and soil. | 290 TL |
| 11-31-01 | Radiation Intensity Data | Solar radiation intensity: 0-1800 W/m 2 | 432 TL |
| 11-31-02 | Temperature (Min., Max., Avg.) Data | Temperature measurement range: (-40) -60 °C | 432 TL |
| 11-31-03 | Relative Humidity Data | Relative humidity measuring range: 0-100% | 432 TL |
| 11-31-04 | Wind Direction and Intensity Data | Wind speed and direction: 1- 67 m/s and 0-360 ° | 432 TL |
| 11-41-01 | Flue Gas Analyzer | 720 TL | |
| 11-42-01 | Thermal Camera | Electrical, mechanical, insulation and handles all the problems with temperature in an open mechanism is used to instantly detect and diagnose. | 720 TL |
| 11-43-01 | Conductivity Meter | 145 TL | |
| 11-44-01 | Steam Trap Tester | Used to detect steam leaks | 216 TL |
| 11-45-01 | Infrared Temperature Meter (Low Temperature) | Temperature measurement range: (-32) -420 °C | 145 TL |
| 11-46-01 | Infrared Temperature Meter (High Temperature) | Temperature measurement range: 200-1800 °C | 145 TL |
| 11-47-01 | Electronic Temperature Meters and Probes | Probes: Surface temperature probe, ambient temperature probe, skewer type temperature probe | 360 TL |
| 11-48-01 | Ultrasonic Flow Meter | It is used to measure the flow of geothermal fluid inside the pipe. | 360 TL |
| 11-49-01 | Electronic Relative Humidity Meter | Portable textile moisture measuring device | 145 TL |
| 11-50-01 | Pitot Tube and Inclined Manometer | 145 TL | |
| 11-51-01 | Hot Wire Air Velocity Meter (Device and Probe) | Used to measure air velocity, temperature, volumetric air flow, relative humidity and pressure | 145 TL |
| 11-52-01 | Propeller Type Air Velocity Meter | It is used to measure and record air velocity and temperature in air ducts. | 145 TL |
| 11-53-01 | Current Clamp | Current meter | 72 TL |
| 11-54-01 | Tachometer | 72 TL | |
| 11-55-01 | Lux-meter | Light intensity measurement | 145 TL |
| 11-56-01 | Sound Level Meter (hour) | Used to determine the level of noise in various environments | 215 TL |
| 11-61-01 | Geothermal Data Assessment Report | Interpretation of hydrological data from geothermal fields | 10.000 TL |
| 11-61-02 | Geothermal Resource Protection Area Report | It will be prepared on the basis of the Law on Geothermal Resources and Mineral Waters Law | 45.000 TL |
| 11-61-03 | 1 / 25.000 Scale Hydrogeological Report (1km 2 ) | Includes the preparation of 1/25.000 scaled Hydrogeological Map for 1 km 2 area and report | 10.000 TL |
| 11-61-04 | Preparation of 1 / 25.000 scaled Geological Maps and Sections that will be the basis for the exploration project of geothermal resources or natural mineral waters | It will be prepared on the basis of the Law on Geothermal Resources and Mineral Waters | 30.000 TL |
| 11-61-05 | Reservoir Modeling Study and Evaluation and Report Preparation of the geothermal resource (includes geology, geophysics, geochemistry, well logs, interpretation of hydrogeology data and modeling of the system) | Covers geology, geophysics, geochemistry, well logs, hydrogeology data interpretation and system modeling | 70.000 TL |
| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 12-01-01 | Anion Analysis (with Ion Chromatography) | F- ,Cl- , Br- ,NO2 - , NO 3 - , SO 4 2- and PO 4 3- one of these anions | 260 TL |
| 12-01-02 | For Each Additional Anion | 60 TL | |
| 12-01-03 | Anion Analysis (with Ion Chromatography) 7 Anions | F- ,Cl- , Br- ,NO2 - , NO 3 - , SO 4 2- and PO 4 3- all of these anions | 620 TL |
| 12-01-04 | Bromate Analysis (with Ion Chromatography) | BrO 3 - ion | 260 TL |
| 12-01-05 | Cation Analyses (with Ion Chromatography) | Li + , Na + , NH 4 + , K + , Mg 2+ and Ca 2+ one of these cations | 260 TL |
| 12-01-06 | For Each Additional Anion | 60 TL | |
| 12-01-07 | Cation Analysis (with Ion Chromatography) 6 Cations | Li + , Na + , NH 4 + , K + , Mg 2+ and Ca 2+ all of these cations | 560 TL |
| 12-01-08 | IC Calibration | Calibration for IC Analysis | 200 TL |
| 12-02-01 | Total Organic Carbon (TOC) | For liquid samples | 180 TL |
| 12-02-02 | Non-Purgeable Organic Carbon (NPOC) | For liquid samples | 180 TL |
| 12-02-03 | Total Organic Carbon (TOC) | For solid samples | 180 TL |
| 12-02-04 | Total Nitrogen (TN) | For liquid samples | 180 TL |
| 12-02-05 | TOC Calibration | Calibration for TOC Analysis | 120 TL |
| 12-02-06 | TN Calibration | Calibration for TN Analysis | 120 TL |
| 12-03-01 | Elemental Analysis with ICP-MS | For 1-10 elements | 375 TL |
| 12-03-02 | Elemental Analysis with ICP-MS | For 11-30 elements | 630 TL |
| 12-03-03 | ICP-MS Calibration | Calibration for ICP-MS Analysis | 240 TL |
| 12-04-01 | Elemental Analysis with ICP-OES | For 1-10 elements | 290 TL |
| 12-04-02 | Elemental Analysis with ICP-OES | For 11-30 elements | 610 TL |
| 12-04-03 | Hg Analysis with ICP-OES | By hydride generation method | 170 TL |
| 12-04-04 | Se Analysis with ICP-OES | By hydride generation method | 170 TL |
| 12-04-05 | Bi Analysis with ICP-OES | By hydride generation method | 170 TL |
| 12-04-06 | Sb Analysis with ICP-OES | By hydride generation method | 170 TL |
| 12-04-07 | ICP-OES Calibration | Calibration for ICP-OES Analysis | 240 TL |
| 12-05-01 | Pellet Preperation | Pellet preperation with KBr for FTIR analysis | 60 TL |
| 12-05-02 | Spectrum Acquisiton with FTIR | (KBr Pellet, DRIFT, ATR) One of these methods is used according to the sample type. | 150 TL |
| 12-06-01 | GC-MS Library Search | 100 TL/hour | |
| 12-06-02 | Qualitative Analysis with GC-MS | 400 TL | |
| 12-06-03 | Quantitative Analysis with GC-MS 1,2 | For 1-10 components | 400 TL |
| 12-06-04 | Quantitative Analysis with GC-MS 1,2 | For 11-30 components | 450 TL |
| 12-06-08 | Qualitative Analysis with SPME GC-MS | 550 TL | |
| 12-06-09 | Quantitative Analysis with SPME GC-MS 1,2 | For 1-10 components | 650 TL |
| 12-06-10 | Quantitative Analysis with SPME GC-MS 1,2 | For 11-20 components | 750 TL |
| 12-06-11 | GC-MS Calibration 1 | Calibration for GC-MS Analysis | 340 TL |
| 12-06-12 | Method Development with GC-MS | 3000 TL | |
| 12-07-01 | Qualitative Analysis with GC-FID | 300 TL | |
| 12-07-02 | Quantitative Analysis with GC-FID 1,2 | For 1-10 components | 350 TL |
| 12-07-03 | Quantitative Analysis with GC-FID 1,2 | For 11-30 components | 400 TL |
| 12-07-04 | Quantitative Analysis with SPME GC-FID 1,2 | For 1-10 components | 500 TL |
| 12-07-05 | Quantitative Analysis with SPME GC-FID 1,2 | For 11-20 components | 600 TL |
| 12-07-06 | GC-FID Calibration 1 | Calibration for GC-FID Analysis | 340 TL |
| 12-07-07 | Method Development with GC-FID | 1500 TL | |
| 12-08-01 | Qualitative Analysis with GC-TCD | 280 TL | |
| 12-09-01 | Qualitative Analysis with HPLC | 250 TL | |
| 12-09-02 | Quantitative Analysis with HPLC 1,2 | For 1-10 components | 300 TL |
| 12-09-03 | Quantitative Analysis with HPLC 1,2 | For 11-20 components | 350 TL |
| 12-09-04 | HPLC Calibration 1 | Calibration for HPLC Analysis | 250 TL |
| 12-09-05 | Method Development with HPLC | 2500 TL | |
| 12-10-01 | Total Alkalinity Analysis | Method: SM 2320 B | 180 TL |
| 12-10-02 | Dissolved Chloride Determination | Method: SM 4500 Cl - D | 130 TL |
| 12-10-03 | Iron (III) Chloride Analysis | 130 TL | |
| 12-11-01 | Microwave Digestion | 210 TL | |
| 12-30-01 | pH | Method: SM 4500-H + B | 50 TL |
| 12-31-01 | Conductivity | Method: SM2510 B | 50 TL |
| 12-32-01 | Temperature Measurement | Method: SM 2550 B | 50 TL |
| 12-33-01 | Total Dissolved Solids (TDS) | Method: SM 2540 C | 100 TL |
| 12-34-01 | Total Hardness | Method: SM 2340 C | 100 TL |
| 12-35-01 | Total Suspended Solid Analysis | Method: SM 2540 D | 175 TL |
| 12-35-03 | Density Measurement | For liquids | 60 TL |
| 12-60-01 | Sample Preperation | For each of the sample preparation steps such as filtering, dissolving, acidification | 150 TL |
| 12-61-01 | Extraction | The price can be changed according to extraction method applied. Please contact our laboratory for details. | 250 TL |
| 12-80-01 | Geothermal Water Analyses Package | Conductivity, pH, hardness, F - ,Cl - , Br - ,NO 2 - , NO 3 - , SO 4 2- and PO 4 3- , Li + , Na + , NH 4 + , K + , Mg 2+ ,Ca 2+ ,B, As, Sr, SiO2, Fe, Ba, TDS, Total Alkalinity | 2400 TL |
| 12-80-02 | Tracer Analyses in Geothermal Waters | Naphthalene Sulfonates | Pricing will be made according to the analysis details. |
| 12-80-03 | Tracer Analyses in Geothermal Waters | Method Development and Calibration | Pricing will be made according to the analysis details. |
| 12-81-01 | Iron (III) Chloride Analysis Used in Drinking Water Treatment | Method: TS EN 888 | 1400 TL |
| 12-81-02 | Analyses of Sodium Hydroxide Which is Used in Drinking Water Treatment | Method: TS EN 869 | 1400 TL |
| 12-20-01 | Faculty Member Report | 2000 TL |
| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 13-01-01 | Agarose Gel Electrophoresis System | For one gel | 108 TL |
| 13-02-01 | Antimicrobial Test 1 | Analysis with two different bacteria (Qualitative Analysis) | 435.6 TL |
| 13-02-02 | Antimicrobial Test 2 | Analysis with two different bacteria (Quantitative Analysis) | 597.6 TL |
| 13-02-03 | Antimicrobial Test 3 | MIC (minimum inhibition concentration)analysis with two different bacteria | 871.2 TL |
| 13-03-01 | Nitrogen Blowdown Evaporator | per hour | 86.4 TL |
| 13-04-01 | Protein and Nitrogen Analysis System (Kjeldahl) | per sample | 86.4 TL |
| 13-05-01 | Bagmixer | per hour | 32.4 TL |
| 13-06-01 | Incubation in shaking Incubator | per day | 54 TL |
| 13-07-01 | DNA Sequencer | PCR purification+ DNA quantitation+Sanger sequencing (F or R direction) | 532.8 TL |
| 13-08-01 | 2D Electrophoresis system | per 2 strips and strips should be supplied by researcher | 817.2 TL |
| 13-09-01 | Fermenter | per day | 219.6 TL |
| 13-10-01 | Fluorescence Microscop(Zeiss) | Monday only for researchers from other universities, per hour | 273 TL |
| 13-11-01 | Flow Cytometer | per tube | 75.6 TL |
| 13-12-01 | FTIR - ATR (Fourier Transform Infrared Spectroscopy- Attenuated Total Reflectance) | sample analysis per hour | 345 TL |
| 13-14-01 | Glove Box | per hour | 43.2 TL |
| 13-14-02 | Glow Box | Per day | 219.6 TL |
| 13-15-01 | Gram Staining | per day | 43.2 TL |
| 13-16-01 | Cell Culture | per day | 36 TL |
| 13-16-02 | Cell Culture Trainning | per training (training max 2 people) | 1800 TL |
| 13-17-01 | Bright field Microscope (inverted) (Zeiss) | per hour Monday only for researchers from other universities | 183 TL |
| 13-17-02 | Bright field Microscope (upright/inverted) (Olympus) | per hour | 108 TL |
| 13-18-01 | Gel Imaging System | per hour | 54 TL |
| 13-19-01 | Micro Dismembrator | per sample | 36 TL |
| 13-20-01 | Chamber Furnace | per day | 43.2 TL |
| 13-21-01 | Liquid Chromatography | per day | 363 TL |
| 13-22-01 | Freeze Dryer | per day | 262.8 TL |
| 13-24-01 | Microsatellite Analysis | per sample | 205.2 TL |
| 13-25-01 | Microtome | per hour | 144 TL |
| 13-26-01 | Autoclave (cell death) | per single use | 24 TL |
| 13-26-02 | Autoclave (sterilization) | per single use | 24 TL |
| 13-27-01 | PCR | per hour | 90 TL |
| 13-28-01 | PFGE (Pulse Field Gel Electrophoresis with enzyme) | per one gel (without enzyme) | 759.6 TL |
| 13-29-01 | PH Meter | per hour | 27 TL |
| 13-30-01 | PH Stat | per day | 32.4 TL |
| 13-31-01 | Real Time PCR | per plate | 225 TL |
| 13-32-01 | Rotary Evaporator | per day | 72 TL |
| 13-33-01 | SDS-PAGE | Per experiment and experiment covers 1 gel run and imaging analysis | 194.4 TL |
| 13-34-01 | Refrigerated Benchtop Centrifuge | per hour | 12 TL |
| 13-35-01 | Speedvac -Vacuum Concentrator | per day | 90 TL |
| 13-36-01 | SPR (Surface Plasmon Resonance) | per hour | 90 TL |
| 13-37-01 | Ultracentrifuge | per single use | 54 TL |
| 13-38-01 | UV Spectrophotometer | per hour | 43.2 TL |
| 13-39-01 | Vacuum Evaporator | per day | 90 TL |
| 13-40-01 | Microplate Reader (24h incubation) | per plate | 453 TL |
| 13-40-02 | Microplate Reader (plate read) | per plate | 135 TL |
| 13-41-01 | Gel Imaging System | per hour | 117 TL |
| 13-42-01 | Fat Analysis System(Rapid Extraction System)per sample | per sample | 63 TL |
| 13-43-01 | HPLC (High Performance Liquid Chromatography) | per day | 117 TL |
| 13-44-01 | Zeta-Sizer 1 | partical size liquid (per hour) | 345 TL |
| 13-44-02 | Zeta-Sizer 2 | zeta potential liquid (per hour) | 363TL |
| 13-44-03 | Zeta-Sizer 3 | zeta potential on solid surface, membrane is supplied by researcher (per hour) | 489.6 TL |
| 13-45-01 | Nanodrop | per hour and device has 8 channels | 72 TL |
| 13-46-01 | Fume Hood | per hour | 15 TL |
| 13-47-01 | Biosafety Cabinet | per hour | 30 TL |
| 13-48-01 | Magnetic Stirrer | per hour | 7.5 TL |
| 13-49-01 | Hot Plate | per hour | 7.5 TL |
| 13-50-01 | Refrigerators | per day | 15 TL |
| 13-51-01 | Oven | per hour | 7.5 TL |
| 13-52-01 | Shaking Water Bath | per hour | 7.5 TL |
| 13-53-01 | Homogenizator | per hour | 15 TL |
| 13-54-01 | Blender | per hour | 15 TL |
| 13-55-01 | Climate Chamber | per day | 45 TL |
| 13-56-01 | Incubator | per day | 30 TL |
| 13-57-01 | Shell Freezer | per hour | 36 TL |
| 13-58-01 | Orbital Shaker - hourly | per hour | 15 TL |
| 13-58-02 | Orbital Shaker - daily | per day | 75 TL |
| 13-59-01 | Membrane Filtration milipore | per day | 60 TL |
| 13-60-01 | Membrane Filtration Sartorius | per day | 60 TL |
| 13-61-01 | Ultrafiltration | per day | 72 TL |
| 13-62-01 | Strain determination | per day | 685.8 TL |
| 13-63-01 | Electroporator | per hour | 36 TL |
| 13-64-01 | Ultrasonic Bath | per hour | 15 TL |
| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 14-01-01 | MALDI TOF MS – Molecular Mass Determination (1-5 Samples) | Mixing sample with matrix is included, the same matrix will be used in all samples. | 1200 TL |
| 14-01-02 | MALDI TOF MS – Molecular Mass Determination (6-10 Samples) | Mixing sample with matrix is included, the same matrix will be used in all samples. | 2000 TL |
| 14-01-03 | MALDI TOF MS – Molecular Mass Determination (11-20 Samples) | Mixing sample with matrix is included, the same matrix will be used in all samples. | 3200 TL |
| 14-01-04 | MS/MS Analysis (per ion) | 160 TL | |
| 14-01-05 | MALDI TOF/TOF MS Protein Identification – Sample preparation not included | It should be pre-cleaned through tryptic treatment, Ziptip etc. | 1600 TL |
| 14-01-06 | MALDI TOF/TOF MS Protein Identification – Sample preparation included | In-sol/in-gel tryptic lysis and Ziptip cleaning are included in the analysis. | 2400 TL |
| 14-02-01 | TRIPLE QUAD Peptide LC MS/MS (1 Sample) | Max. 1 hour analysis Not for complex samples | 1600 TL |
| 14-02-02 | TRIPLE QUAD Peptide LC MS/MS (Sample repetition) | 960 TL | |
| 14 -03-01 | Orbitrap high resolution nanoLC-MS 90 min. Proteomic analysis | Peptide analysis with nanoLC, number of samples <20, per sample | 5000 TL |
| 14-03-02 | Orbitrap high resolution nanoLC-MS 150 min. Proteomic analysis | Peptide analysis with nanoLC, number of samples <20, per sample | 7000 TL |
| 14-03-03 | Orbitrap high resolution nanoLC-MS 90 min. Proteomic analysis (conditional discount) | Peptide analysis with nanoLC, number of samples >20, per sample | 3500 TL |
| 14-03-04 | Orbitrap high resolution nanoLC-MS 150 min. Proteomic analysis (conditional discount) | Peptide analysis with nanoLC, number of samples >20, per sample | 4900 TL |
| 14-03-05 | Sample preparation with FASP tryptic digestion | It is applied to protein mixture. | 1500 TL |
| Analysis Code | Analysis Name | Explanation | Price |
|---|---|---|---|
| 15-01-01 | 1H (Proton) NMR Spectrum | 160 TL | |
| 15-01-02 | 13C (Carbon) NMR Spectrum (0-1 hour) | 300 TL | |
| 15-01-03 | APT | 325 TL | |
| 15-01-04 | DEPT | 325 TL | |
| 15-01-05 | COSY | 325 TL | |
| 15-01-06 | NOESY | 400 TL | |
| 15-01-07 | ROESY | 400 TL | |
| 15-01-08 | TOCSY | 400 TL | |
| 15-01-09 | HMBC | 430 TL | |
| 15-01-10 | HMQC | 430 TL | |
| 15-01-11 | HSQC | 430 TL | |
| 15-01-12 | 31P (Phosphorous) NMR Spectrum | 320 TL | |
| 15-01-13 | 19F (Florine) NMR Spectrum | 320 TL | |
| 15-01-14 | 11B (Boron) NMR Spectrum | 340 TL | |
| 15-01-15 | 13C (Carbon) NMR Spectrum (1-3 hrs) | 400 TL | |
| 15-01-16 | 13C (Carbon) NMR Spectrum(Overnight) | 600 TL | |
| Solvent | Price |
||
| CDCl3 | 120 TL |
||
| DMSO-D6 | 230 TL |
||
| D2O | 150 TL |
||
| Aceton-D6 | 250 TL |
||
| CD3OD | 250 TL |
||
| Benzene-D6 | 350 TL |
* Do not include solvent and sampling price .
** The following fees are charged for each sample prepared, depending on the solvent type.