2023 IRC Price Lists

* Prices are valid between 01.01.2023 – 31.12.2023, 18% VAT is not included.

CMR Price List

Analysis CodeAnalysis NameExplanation Price
10-01-01TEM AnalysisThe device is not available for use
10-02-01SEM Analysis An average of 6 samples can be investigated in 1 hour.
The samples should not contain moisture/oil.
500 TL/hr
10-02-02EDX AnalysisAn average of 6 samples can be investigated in 1 hour.
The samples should not contain moisture/oil.
600 TL/hr
10-02-03STEM AnalysisAn average of 2 samples can be investigated in 1 hour.
The samples should not contain moisture/oil and should be prepared on TEM grid.
900 TL/hr
10-02-04ESEM AnalysisAn average of 3 samples can be investigated in 1 hour. 900 TL/hr
10-02-05WETSTEM AnalysisPlease make an appointment for SEM2 machine only Wednesday.
You should contact the lecturer for sample suitability.
1500 TL/hr
10-02-06SEM - UserPeople who have taken SEM training and have been granted a right to use it can make an online appointment.125 TL/hr
10-03-01AFM AnalysisThe sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed.
900 TL/hr
10-03-02Fulid CellThe sample should be maximum 1 cm X 1 cm X 0.5 cm.
The sample must be fixed to the surface.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed.
1200 TL/hr
10-03-03Peak Force QNMThe sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed.
2000 TL/hr
10-03-04IndentationThe sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Powder sample cannot be analyzed.
2000 TL/hr
10-04-01STM The sample size should be maximum 1 cm X 1 cm X 0.5 cm.
The sample should not contain moisture/oil.
Samples must be conductive.
Powder sample cannot be analyzed.
2000 TL/hr
10-11-01EDXRF The sample should be at least 1 g.
Particle size should be less than 100 microns. (If it is not in the desired size, the grinding option should be selected)
Solid samples 32 mm or 40 mm diameter, maximum 10 mm height should be.
When Fusion is desired, "Loss of Ignition" and "Fusion" pre-preparation processes should be selected.
When the necessary preparation procedures are not selected, additions will be made by the expert.
300 TL/piece
10-12-01XRD Fast Scan Analysis (Standard), 0.08 ∘∕s , ∼17minThe amount of the sample must be the 1/4 of an eppendorf tube.
Sample must be in fine powder form (100µ >).
Scan range must be specified in the request form.
200 TL/piece
10-12-02XRD MediumScan Analysis (Standard), 0.04 ∘∕s, ∼ 33minThe amount of the sample must be the 1/4 of an eppendorf tube.
Sample must be in fine powder form (100µ >)
Scan range must be specified in the request form.
250 TL/piece
10-12-03XRD Low Scan Analysis (Standard), 0.02 ∘∕s, ∼65minThe amount of the sample must be the 1/4 of an eppendorf tube.
Sample must be in fine powder form (100µ >)
Scan range must be specified in the request form.
300 TL/piece
10-12-04Crystal Structure AnalysisXRD Analysis must have been acquired in IYTE CMR250 TL/hr
10-14-01Spectrofluorometer (Solid Samples)Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm
Solid samples should be prepared as thin films.
200 TL/hr
10-14-02Spectrofluorometer (Liquid Samples)Laser Sources for LifeTime Measurements: EPLED - 300 ± 10 nm; EPL - 450 ± 10 nm; EPLED - 560 ± 10 nm
Amount of sample should be at least 100 μL.
Liquid samples should be sent with their solvent.
Samples should be sent with cuvettes. For Quantum Yield measurements, screw cap cuvettes are required.
200 TL/hr
10-21-01TGA Analysis - 1 hourSample amount should be between 3-10 mg. 350 TL/piece
10-21-02TGA Analysis - 2 hoursSample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C.450 TL/piece
10-21-03TGA Analysis - 3 hoursSample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C.550 TL/piece
10-21-04TGA Analysis - 4 hoursSample amount should be between 3-10 mg. The device reaches a maximum of 1200 °C.650 TL/piece
10-22-01DSC Analysis- 1 hourSample amount should be between 3-10 mg. The device works between -40 °C and 350 °C.350 TL/piece
10-22-02DSC Analysis-2 hoursSample amount should be between 3-10 mg. The device works between -40 °C and 350 °C.450 TL/piece
10-22-03DSC Analysis-3 hoursSample amount should be between 3-10 mg. The device works between -40 °C and 350 °C.550 TL/piece
10-22-04DSC Analysis-4 hoursSample amount should be between 3-10 mg. The device works between -40 °C and 350 °C.650 TL/piece
10-23-01DilatometerThe device reaches a maximum of 1200 °C. Please contact the specialist to specify the size of your sample.400 TL/piece
10-31-01BET AnalysisSample amount should be at least 300 mg. Degas conditions must be specified.500 TL/piece
10-31-02BET (Adsorption/Desorption)Sample amount should be at least 300 mg. Degas conditions must be specified.700 TL/piece
10-32-01TensileThe thickness of the samples should be 8 mm maximum. The lecturer should be contacted.250 TL/piece
10-32-02CompressionThe lecturer should be contacted.250 TL/piece
10-32-03High Temperature Tensile TestingThe lecturer should be contacted.600 TL/piece
10-33-01Lecturer ReportIt is prepared by the lecturer who is the expert of the device.1000 TL/piece
10-33-02Faculty Member ReportIt is prepared by member of teaching of IZTECH2000 TL/piece
Coating40 TL/piece
XRF Fusion120 TL/piece
Milling100 TL/piece
Loss of Ignition120 TL/piece

GEOCEN Price List

Analysis CodeAnalysis NameExplanationPrice
11-01-01Heat Capacity Measurement (with DSC)Appointment is required360 TL
11-01-02Determination of Melting Point and Glass Transition Temperature-between ambient temperature - 500 C temperatures (with DSC)Working range: Room temp.- 550 C430 TL
11-01-03Determination of Melting Point and Glass Transition Temperature - between (-40) - 400 C temperatures (with DSC)Working range:(-40) - 400 C290 TL
11-02-01Dew Point Temperature MeasurementDetermination of dew point temperature in systems where humid air is used70 TL
11-03-01Viscosity MeasurementFluidity determination145 TL
11-04-01Heat Conduction Coefficient Measurement (KEM-QTM500)Measuring range: 0.026-12 W/mK Minimum sample size: 2x6x12 cm190 TL
11-05-01Silica MeasurementMeasuring range: 1 - 100 mg/L SiO 2170 TL
11-06-01Heat Conduction Coefficient Measurement (TA-FOX314)Measuring range: 0.005-0.35 W/mK 840 TL
11-07-01Heat Conduction Coefficient Measurement (TA-FOX50)Measuring range: 0.1-10 W/mK840 TL
11-08-01pH Measurement (Hach HQ2200)Prices are valid for laboratory analysis.50 TL
11-08-02Electrical Conductivity Measurement (Hach HQ2200)Prices are valid for laboratory analysis.50 TL
11-08-03Dissolved Oxygen Measurement (LDO)-(Hach HQ2200)Prices are valid for laboratory analysis.50 TL
11-08-04Analyses Pack pH-EC-LDO (Hach HQ2200)Prices are valid for laboratory analysis.130 TL
11-11-01Particle CountDetermination of airborne particle count215 TL
11-12-01Building Indoor Air Quality MonitorCO 2 , CO, Temperature, Relative Humidity290 TL
11-13-01Thermal Comfort SystemTemperature, air velocity, relative humidity, operative temperature, radiation temperature and dry heat loss temperature1440 TL
11-21-01Downhole Temperature Measurement (per measurement)Get information from the expert2160 TL
11-21-01Downhole Pressure Measurement (per measurement)Get information from the expert2160 TL
11-22-01Tracer testsIt is used to determine the flow rate and groundwater flow direction.7200 TL
11-23-01Radon Level Measurement (per point)It is used for Radon gas determination in water, air and soil.290 TL
11-31-01Radiation Intensity DataSolar radiation intensity: 0-1800 W/m 2432 TL
11-31-02Temperature (Min., Max., Avg.) DataTemperature measurement range: (-40) -60 °C432 TL
11-31-03Relative Humidity DataRelative humidity measuring range: 0-100%432 TL
11-31-04Wind Direction and Intensity DataWind speed and direction: 1- 67 m/s and 0-360 °432 TL
11-41-01Flue Gas Analyzer720 TL
11-42-01Thermal CameraElectrical, mechanical, insulation and handles all the problems with temperature in an open mechanism is used to instantly detect and diagnose.720 TL
11-43-01Conductivity Meter145 TL
11-44-01Steam Trap TesterUsed to detect steam leaks216 TL
11-45-01Infrared Temperature Meter (Low Temperature)Temperature measurement range: (-32) -420 °C145 TL
11-46-01Infrared Temperature Meter (High Temperature)Temperature measurement range: 200-1800 °C145 TL
11-47-01Electronic Temperature Meters and ProbesProbes: Surface temperature probe, ambient temperature probe, skewer type temperature probe360 TL
11-48-01Ultrasonic Flow MeterIt is used to measure the flow of geothermal fluid inside the pipe.360 TL
11-49-01Electronic Relative Humidity MeterPortable textile moisture measuring device145 TL
11-50-01Pitot Tube and Inclined Manometer145 TL
11-51-01Hot Wire Air Velocity Meter (Device and Probe)Used to measure air velocity, temperature, volumetric air flow, relative humidity and pressure145 TL
11-52-01Propeller Type Air Velocity MeterIt is used to measure and record air velocity and temperature in air ducts.145 TL
11-53-01Current ClampCurrent meter72 TL
11-54-01Tachometer72 TL
11-55-01Lux-meterLight intensity measurement145 TL
11-56-01Sound Level Meter (hour)Used to determine the level of noise in various environments215 TL
11-61-01 Geothermal Data Assessment ReportInterpretation of hydrological data from geothermal fields10.000 TL
11-61-02Geothermal Resource Protection Area ReportIt will be prepared on the basis of the Law on Geothermal Resources and Mineral Waters Law45.000 TL
11-61-031 / 25.000 Scale Hydrogeological Report (1km 2 )Includes the preparation of 1/25.000 scaled Hydrogeological Map for 1 km 2 area and report10.000 TL
11-61-04Preparation of 1 / 25.000 scaled Geological Maps and Sections that will be the basis for the exploration project of geothermal resources or natural mineral watersIt will be prepared on the basis of the Law on Geothermal Resources and Mineral Waters30.000 TL
11-61-05Reservoir Modeling Study and Evaluation and Report Preparation of the geothermal resource (includes geology, geophysics, geochemistry, well logs, interpretation of hydrogeology data and modeling of the system)Covers geology, geophysics, geochemistry, well logs, hydrogeology data interpretation and system modeling70.000 TL

ENVIROCEN Price List

Analysis CodeAnalysis NameExplanationPrice
12-01-01Anion Analysis (with Ion Chromatography) F- ,Cl- , Br- ,NO2 - , NO 3 - , SO 4 2- and PO 4 3- one of these anions260 TL
12-01-02For Each Additional Anion 60 TL
12-01-03Anion Analysis (with Ion Chromatography) 7 AnionsF- ,Cl- , Br- ,NO2 - , NO 3 - , SO 4 2- and PO 4 3- all of these anions620 TL
12-01-04Bromate Analysis (with Ion Chromatography)BrO 3 - ion260 TL
12-01-05Cation Analyses (with Ion Chromatography)Li + , Na + , NH 4 + , K + , Mg 2+ and Ca 2+ one of these cations260 TL
12-01-06For Each Additional Anion 60 TL
12-01-07Cation Analysis (with Ion Chromatography) 6 CationsLi + , Na + , NH 4 + , K + , Mg 2+ and Ca 2+ all of these cations560 TL
12-01-08IC CalibrationCalibration for IC Analysis200 TL
12-02-01Total Organic Carbon (TOC)For liquid samples180 TL
12-02-02Non-Purgeable Organic Carbon (NPOC)For liquid samples180 TL
12-02-03Total Organic Carbon (TOC)For solid samples180 TL
12-02-04Total Nitrogen (TN)For liquid samples180 TL
12-02-05TOC CalibrationCalibration for TOC Analysis120 TL
12-02-06TN CalibrationCalibration for TN Analysis120 TL
12-03-01Elemental Analysis with ICP-MS For 1-10 elements375 TL
12-03-02Elemental Analysis with ICP-MSFor 11-30 elements630 TL
12-03-03ICP-MS CalibrationCalibration for ICP-MS Analysis240 TL
12-04-01Elemental Analysis with ICP-OESFor 1-10 elements290 TL
12-04-02Elemental Analysis with ICP-OESFor 11-30 elements610 TL
12-04-03Hg Analysis with ICP-OESBy hydride generation method170 TL
12-04-04Se Analysis with ICP-OESBy hydride generation method170 TL
12-04-05Bi Analysis with ICP-OESBy hydride generation method170 TL
12-04-06Sb Analysis with ICP-OESBy hydride generation method170 TL
12-04-07ICP-OES CalibrationCalibration for ICP-OES Analysis240 TL
12-05-01Pellet PreperationPellet preperation with KBr for FTIR analysis60 TL
12-05-02Spectrum Acquisiton with FTIR (KBr Pellet, DRIFT, ATR) One of these methods is used according to the sample type.150 TL
12-06-01GC-MS Library Search100 TL/hour
12-06-02Qualitative Analysis with GC-MS400 TL
12-06-03Quantitative Analysis with GC-MS 1,2For 1-10 components400 TL
12-06-04Quantitative Analysis with GC-MS 1,2For 11-30 components450 TL
12-06-08Qualitative Analysis with SPME GC-MS550 TL
12-06-09Quantitative Analysis with SPME GC-MS 1,2For 1-10 components650 TL
12-06-10Quantitative Analysis with SPME GC-MS 1,2For 11-20 components750 TL
12-06-11GC-MS Calibration 1Calibration for GC-MS Analysis340 TL
12-06-12Method Development with GC-MS 3000 TL
12-07-01Qualitative Analysis with GC-FID300 TL
12-07-02Quantitative Analysis with GC-FID 1,2For 1-10 components350 TL
12-07-03Quantitative Analysis with GC-FID 1,2For 11-30 components400 TL
12-07-04Quantitative Analysis with SPME GC-FID 1,2For 1-10 components500 TL
12-07-05Quantitative Analysis with SPME GC-FID 1,2For 11-20 components600 TL
12-07-06GC-FID Calibration 1Calibration for GC-FID Analysis340 TL
12-07-07Method Development with GC-FID1500 TL
12-08-01Qualitative Analysis with GC-TCD280 TL
12-09-01Qualitative Analysis with HPLC250 TL
12-09-02Quantitative Analysis with HPLC 1,2For 1-10 components300 TL
12-09-03Quantitative Analysis with HPLC 1,2For 11-20 components350 TL
12-09-04HPLC Calibration 1Calibration for HPLC Analysis250 TL
12-09-05Method Development with HPLC2500 TL
12-10-01Total Alkalinity AnalysisMethod: SM 2320 B180 TL
12-10-02Dissolved Chloride DeterminationMethod: SM 4500 Cl - D130 TL
12-10-03Iron (III) Chloride Analysis130 TL
12-11-01Microwave Digestion210 TL
12-30-01pH Method: SM 4500-H + B50 TL
12-31-01ConductivityMethod: SM2510 B50 TL
12-32-01Temperature MeasurementMethod: SM 2550 B50 TL
12-33-01Total Dissolved Solids (TDS)Method: SM 2540 C100 TL
12-34-01Total HardnessMethod: SM 2340 C100 TL
12-35-01Total Suspended Solid Analysis Method: SM 2540 D175 TL
12-35-03Density MeasurementFor liquids60 TL
12-60-01Sample PreperationFor each of the sample preparation steps such as filtering, dissolving, acidification150 TL
12-61-01ExtractionThe price can be changed according to extraction method applied. Please contact our laboratory for details.250 TL
12-80-01Geothermal Water Analyses PackageConductivity, pH, hardness, F - ,Cl - , Br - ,NO 2 - , NO 3 - , SO 4 2- and PO 4 3- , Li + , Na + , NH 4 + , K + , Mg 2+ ,Ca 2+ ,B, As, Sr, SiO2, Fe, Ba, TDS, Total Alkalinity2400 TL
12-80-02Tracer Analyses in Geothermal WatersNaphthalene SulfonatesPricing will be made according to the analysis details.
12-80-03Tracer Analyses in Geothermal WatersMethod Development and CalibrationPricing will be made according to the analysis details.
12-81-01Iron (III) Chloride Analysis Used in Drinking Water TreatmentMethod: TS EN 8881400 TL
12-81-02Analyses of Sodium Hydroxide Which is Used in Drinking Water TreatmentMethod: TS EN 8691400 TL
12-20-01Faculty Member Report2000 TL

NOTES :

  1. For the analysis from IZTECH, column, standards and solvents, etc according to the anlysis method should be supplied by IZTECH
  2. In cases where the number of samples and components is high, the price is determined by considering the sample feature and the scope of the study.

CFB Price List

Analysis CodeAnalysis NameExplanationPrice
13-01-01Agarose Gel Electrophoresis SystemFor one gel108 TL
13-02-01Antimicrobial Test 1Analysis with two different bacteria (Qualitative Analysis)435.6 TL
13-02-02Antimicrobial Test 2Analysis with two different bacteria (Quantitative Analysis)597.6 TL
13-02-03Antimicrobial Test 3 MIC (minimum inhibition concentration)analysis with two different bacteria871.2 TL
13-03-01Nitrogen Blowdown Evaporatorper hour86.4 TL
13-04-01Protein and Nitrogen Analysis System (Kjeldahl)per sample86.4 TL
13-05-01Bagmixerper hour32.4 TL
13-06-01Incubation in shaking Incubatorper day54 TL
13-07-01DNA SequencerPCR purification+ DNA quantitation+Sanger sequencing (F or R direction)532.8 TL
13-08-012D Electrophoresis systemper 2 strips and strips should be supplied by researcher817.2 TL
13-09-01Fermenterper day219.6 TL
13-10-01Fluorescence Microscop(Zeiss)Monday only for researchers from other universities, per hour273 TL
13-11-01Flow Cytometerper tube75.6 TL
13-12-01FTIR - ATR (Fourier Transform Infrared Spectroscopy- Attenuated Total Reflectance)sample analysis per hour345 TL
13-14-01Glove Boxper hour43.2 TL
13-14-02Glow Box Per day219.6 TL
13-15-01Gram Staining per day43.2 TL
13-16-01Cell Cultureper day36 TL
13-16-02Cell Culture Trainningper training (training max 2 people)1800 TL
13-17-01Bright field Microscope (inverted) (Zeiss)per hour Monday only for researchers from other universities183 TL
13-17-02Bright field Microscope (upright/inverted) (Olympus)per hour108 TL
13-18-01Gel Imaging Systemper hour54 TL
13-19-01Micro Dismembratorper sample36 TL
13-20-01Chamber Furnaceper day43.2 TL
13-21-01Liquid Chromatographyper day363 TL
13-22-01Freeze Dryerper day262.8 TL
13-24-01Microsatellite Analysisper sample205.2 TL
13-25-01Microtomeper hour144 TL
13-26-01Autoclave (cell death)per single use24 TL
13-26-02Autoclave (sterilization)per single use24 TL
13-27-01PCR per hour90 TL
13-28-01PFGE (Pulse Field Gel Electrophoresis with enzyme)per one gel (without enzyme)759.6 TL
13-29-01PH Meterper hour27 TL
13-30-01PH Statper day32.4 TL
13-31-01Real Time PCRper plate225 TL
13-32-01Rotary Evaporatorper day72 TL
13-33-01SDS-PAGEPer experiment and experiment covers 1 gel run and imaging analysis194.4 TL
13-34-01Refrigerated Benchtop Centrifugeper hour12 TL
13-35-01Speedvac -Vacuum Concentratorper day90 TL
13-36-01SPR (Surface Plasmon Resonance)per hour90 TL
13-37-01Ultracentrifugeper single use54 TL
13-38-01UV Spectrophotometerper hour43.2 TL
13-39-01Vacuum Evaporatorper day90 TL
13-40-01Microplate Reader (24h incubation)per plate453 TL
13-40-02Microplate Reader (plate read)per plate135 TL
13-41-01Gel Imaging Systemper hour117 TL
13-42-01Fat Analysis System(Rapid Extraction System)per sampleper sample63 TL
13-43-01HPLC (High Performance Liquid Chromatography)per day117 TL
13-44-01Zeta-Sizer 1partical size liquid (per hour)345 TL
13-44-02Zeta-Sizer 2zeta potential liquid (per hour)363TL
13-44-03Zeta-Sizer 3zeta potential on solid surface, membrane is supplied by researcher (per hour)489.6 TL
13-45-01Nanodropper hour and device has 8 channels72 TL
13-46-01Fume Hoodper hour15 TL
13-47-01Biosafety Cabinetper hour30 TL
13-48-01Magnetic Stirrerper hour7.5 TL
13-49-01Hot Plateper hour7.5 TL
13-50-01Refrigeratorsper day15 TL
13-51-01Ovenper hour7.5 TL
13-52-01Shaking Water Bathper hour7.5 TL
13-53-01Homogenizatorper hour15 TL
13-54-01Blenderper hour15 TL
13-55-01Climate Chamberper day45 TL
13-56-01Incubatorper day30 TL
13-57-01Shell Freezerper hour36 TL
13-58-01Orbital Shaker - hourlyper hour15 TL
13-58-02Orbital Shaker - dailyper day75 TL
13-59-01Membrane Filtration miliporeper day60 TL
13-60-01Membrane Filtration Sartoriusper day60 TL
13-61-01Ultrafiltrationper day72 TL
13-62-01Strain determinationper day685.8 TL
13-63-01Electroporatorper hour36 TL
13-64-01Ultrasonic Bathper hour15 TL

NMSC Price List

Analysis CodeAnalysis NameExplanationPrice
14-01-01MALDI TOF MS – Molecular Mass Determination
(1-5 Samples)
Mixing sample with matrix is included, the same matrix will be
used in all samples.
1200 TL
14-01-02MALDI TOF MS – Molecular Mass Determination
(6-10 Samples)
Mixing sample with matrix is included, the same matrix will be used in all samples.
2000 TL
14-01-03MALDI TOF MS – Molecular Mass Determination
(11-20 Samples)
Mixing sample with matrix is included, the same matrix will be
used in all samples.
3200 TL
14-01-04MS/MS Analysis (per ion)160 TL
14-01-05MALDI TOF/TOF MS Protein Identification – Sample preparation not
included
It should be pre-cleaned through tryptic treatment, Ziptip etc.1600 TL
14-01-06MALDI TOF/TOF MS Protein Identification – Sample preparation includedIn-sol/in-gel tryptic lysis and Ziptip cleaning are included in the
analysis.
2400 TL
14-02-01TRIPLE QUAD Peptide LC MS/MS (1 Sample) Max. 1 hour analysis
Not for complex samples
1600 TL
14-02-02TRIPLE QUAD Peptide LC MS/MS (Sample repetition)960 TL
14 -03-01Orbitrap high resolution nanoLC-MS 90 min. Proteomic analysisPeptide analysis with nanoLC, number of samples <20, per sample5000 TL
14-03-02Orbitrap high resolution nanoLC-MS 150 min. Proteomic analysisPeptide analysis with nanoLC, number of samples <20, per sample7000 TL
14-03-03Orbitrap high resolution nanoLC-MS 90 min. Proteomic analysis (conditional discount)Peptide analysis with nanoLC, number of samples >20, per sample3500 TL
14-03-04Orbitrap high resolution nanoLC-MS 150 min. Proteomic analysis (conditional discount)Peptide analysis with nanoLC, number of samples >20, per sample4900 TL
14-03-05Sample preparation with FASP tryptic digestionIt is applied to protein mixture.1500 TL

NOTES :

  1. For bioinformatic analysis requiring peptide ID, protein database should be given in FASTA format, otherwise the reference proteome of the relevant organism is used via UniProt.
  2. Analyzes coded 14-01-05 and 14-01-06 include MS/MS analysis of at least 2 peptides with the strongest signals and database search with Mascot.
  3. For different methods than the ones requested in the 14-02-01 and 14-02-02 coded analyzes, the column, standard, solvents and literature study should be supplied by the user after the feasibility of the study is confirmed by the center.
  4. Standard shotgun method applied is DDA and label-free comparison is done for the analysis beginning with 14-03 code. Materials and applications specific to the study prior to sample preparation are the responsibility of the user. For detailed information, please contact the center.

NMR Price List

Analysis CodeAnalysis NameExplanationPrice
15-01-011H (Proton) NMR Spectrum160 TL
15-01-0213C (Carbon) NMR Spectrum (0-1 hour)300 TL
15-01-03APT325 TL
15-01-04DEPT325 TL
15-01-05COSY325 TL
15-01-06NOESY400 TL
15-01-07ROESY400 TL
15-01-08TOCSY400 TL
15-01-09HMBC430 TL
15-01-10HMQC430 TL
15-01-11HSQC430 TL
15-01-1231P (Phosphorous) NMR Spectrum320 TL
15-01-1319F (Florine) NMR Spectrum320 TL
15-01-1411B (Boron) NMR Spectrum340 TL
15-01-1513C (Carbon) NMR Spectrum (1-3 hrs)400 TL
15-01-1613C (Carbon) NMR Spectrum(Overnight)600 TL
SolventPrice
CDCl3
120 TL
DMSO-D6
230 TL
D2O
150 TL
Aceton-D6
250 TL
CD3OD
250 TL
Benzene-D6
350 TL

NOTES :

*  Do not include solvent and sampling price .

** The following fees are charged for each sample prepared, depending on the solvent type.